Sign In | Join Free | My himfr.com
Home > Compressor Condensing Unit >

Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

DONGGUAN HUAXIAN LTD.
Contact Now
    Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
     
    Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers
    • Buy cheap Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer from wholesalers

    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

    Ask Lasest Price
    Brand Name : HUAXIAN
    Model Number : HX
    Certification : ISO
    Price : USD2000~5000/set
    Supply Ability : 100sets/month
    Delivery Time : 30 work days
    • Product Details
    • Company Profile

    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

    Box Type Outdoor Compressor Condensing Unit For Walk In Freezer


    The refrigeration compression condensing unit is composed of one or several refrigeration compressors, oil separators, condensers, liquid receivers (if necessary), dry filters and accessories. Used to compress and liquefy refrigerants. Commonly used in cold storage.


    How to maintain the compression condensing unit:


    1. Regularly check the compressor of the air-cooled condensing unit
    The compressor is the "heart" of the air-cooled compression condensing unit. Its quality directly affects the stability of the air-cooled compression condensing unit. If the compressor fails to repair, the cost is relatively high, especially the price of the compressor. Therefore, if you hear abnormal sound from the compressor or other conditions, you must contact the air-cooled compressor condensing unit factory to find a professional engineer to check, find out the cause and perform repairs.


    2. Regularly clean the condenser and evaporator of the air-cooled compression condensing unit
    The condenser/evaporator is the second most important component of the air-cooled compression condensing unit and should be cleaned every six months. The cooling water of the water-cooled condenser is an open circulation loop. The tap water used is recycled through the cooling water tower. It is easy to decompose and deposit impurities to form scale on the water pipe, which affects the heat transfer effect. Excessive scaling will also reduce the circulation section of cooling water, reduce the amount of water, and increase the condensation pressure. Therefore, when the quality of the tap water used is poor, it should be cleaned at least once a year to remove the scale in the pipe and perform water treatment operations on the tap water.


    3. Regularly check the chilled water unit passing through the safety valve
    The condenser and evaporator of the air-cooled compression condensing unit belong to their own pressure and container. According to relevant regulations, a safety valve should be installed on the high-pressure end of the air-cooled compression condensing unit, that is, the condenser body. Once the unit is in an abnormal condition In the working and living environment, the safety valve can realize automatic pressure relief to prevent damage and loss caused by high pressure.


    4. Regular replacement
    The air-cooled compression condensing unit uses lubricating oil. After the air-cooled condensing unit is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture in the oil will increase. The oil quality should be observed and checked regularly. Once a problem is found, it should be replaced in time. The brand of lubricating oil to be replaced is subject to the original manufacturer.


    5. Regularly replace the drying filter of the air-cooled compresser condensing unit
    The dry filter is an important component to ensure the normal development cycle of the refrigerant. Since water and refrigerant are incompatible with each other, if a system contains water, it will greatly affect the operating efficiency of the air-cooled compression condensing unit. Therefore, internal control of drying is very important, and the filter element inside the drying filter must be replaced regularly.




    Components


    No.NameBrand
    1CompressorBITZER, COPELAND, REFCOMP, HANBELL, etc
    2CondenserKAILAILI or YONGQIANG
    3FilterDANFOSS
    4Ball valveDANFOSS
    5Solenoid valveDANFOSS
    6Sight glassDANFOSS
    7Pressure controllerDANFOSS
    8Pressure gaugeREFCO



    Product Picture for Reference


    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer



    Successful Case


    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In FreezerOutdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer

    Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer




    FAQ:


    1.Can the refrigeration unit be customized?

    • Yes. The refrigeration unit (compressor condenser unit) can be customized according to customer's requirement.

    2.Can the refrigeration unit be made single phase?

    • Yes. But the max compressor for single phase is 3HP. More than 3HP, it should be 3 phase.

    3.Can the refrigeration unit be place outdoor?

    • Yes. Our compressor condenser unit is box type. We still recommend building a shed for it, which will keep it safe from severe weather.

    4.How's the package of shipment?

    • The compressor condenser unit is packaged by wooden frame for safety shipment.

    5.What's the payment terms?

    • By T/T, 30% deposit, 70% will be paid before shipment.

    6.What's the lead time?

    • The production lead time is 30 working days, plus 30 days shipping time. Some countries will be longer for sailing.

    Quality Outdoor Compressor Condensing Unit Air Cooled 10HP Box For Walk In Freezer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN HUAXIAN LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)